Troubleshooting and Maintenance

Ensure your emergency lift phone is operational and compliant with these troubleshooting tips and maintenance best practices.

Updated over a month ago

Troubleshooting Common Issues

1. No Dial Tone

  • Check Power Supply:

    • Verify that the lift phone is connected to a functioning power source.

    • Confirm that the backup battery is charged and operational.

  • Inspect Phone Line or Network Connection:

    • Ensure cables are securely connected to the correct ports.

    • For digital or cellular systems, check for network coverage or signal strength.

  • Action: If unresolved, contact Pickle Support for further assistance.


2. Unable to Connect to Monitoring Service

  • Test the Connection:

    • Dial the monitoring service manually to confirm the connection.

    • Use a different phone line or network to verify if the issue is specific to the lift phone.

  • Check Compliance Settings:

    • Confirm the phone's configuration matches the monitoring service's requirements.

  • Action: Reset the system and test again. If the issue persists, escalate to a technician.


3. Weak or Intermittent Signal (Cellular Systems)

  • Inspect Signal Strength:

    • Check the modem or signal indicator on the lift phone system.

    • Relocate the antenna or install a signal booster if the signal is weak.

  • Action: Contact your network provider if coverage issues persist.


4. Backup Battery Not Functioning

  • Battery Check:

    • Inspect for physical damage or swelling.

    • Use a multimeter to check the voltage.

  • Action: Replace the battery if it fails to meet the required voltage level.


5. False Alarms or System Alerts

  • Verify Alerts:

    • Review the system logs or monitor for error codes.

    • Test the functionality to ensure there is no actual issue.

  • Action: Reset the system and observe for recurring issues. Consult a technician if alerts persist.


Maintenance Guidelines

1. Regular Testing

  • Perform monthly tests to ensure:

    • A stable dial tone is present.

    • The phone connects reliably to the monitoring service.

  • Document all test results for compliance and record-keeping.


2. Backup Power Maintenance

  • Inspect and replace the backup battery every 12 months or as needed.

  • Ensure the battery provides at least two hours of operation during power outages.

  • Test the backup system quarterly to confirm reliability.


3. System Updates

  • Check for firmware or software updates periodically.

  • Install updates to ensure compatibility with the latest network technologies.


4. Visual and Physical Inspection

  • Look for wear and tear on cables, ports, and the device casing.

  • Ensure no obstructions block access to the phone or its components.


5. Annual Professional Inspection

  • Schedule a licensed technician to inspect the system annually.

  • The inspection should include:

    • Verification of compliance with Australian standards.

    • Testing of both primary and secondary communication pathways.


Escalating Issues

If troubleshooting and maintenance do not resolve the problem:

  1. Contact Pickle Support for advanced diagnostics.

  2. Provide details such as:

    • Error codes or symptoms.

    • Actions taken during troubleshooting.

    • Recent maintenance or system changes.

  3. Schedule a technician if necessary to repair or replace faulty components.


By following these troubleshooting and maintenance steps, you can ensure that your emergency lift phone remains operational, compliant, and ready to provide reliable communication when needed. For additional support, reach out to Pickle Support anytime.